{"title":"Controlled Atmosphere Systems","description":"\u003cp\u003e\u003cstrong\u003eBattery chemistries that fail on contact with ambient O2 or H2O — lithium metal, sodium metal, sulfide solid electrolytes, LiPF6-based liquid electrolytes — only work inside a controlled atmosphere, and the practical question is whether you need a sealed inert envelope, a low-humidity room, or both.\u003c\/strong\u003e This collection groups the two infrastructure tiers that almost every battery lab and pilot line eventually buys: glovebox workstations for sub-ppm O2\/H2O work, and dryrooms for whole-workflow humidity control.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/collections\/gloveboxes\"\u003eGloveboxes\u003c\/a\u003e.\u003c\/strong\u003e Sealed argon (or nitrogen) chambers with regenerable copper-catalyst and molecular-sieve purification, antechambers, and integration ports. The right tool for coin-cell and pouch-cell assembly, lithium-metal handling, sulfide solid-electrolyte work, and any step that has to stay below the ppm range for moisture and oxygen.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/collections\/dryrooms\"\u003eDryrooms\u003c\/a\u003e.\u003c\/strong\u003e Sub-1% RH enclosures specified by dew point (-40 C for entry-level Li-ion R\u0026amp;D, -50 to -60 C for production-representative assembly, -70 C and below for lithium-metal and solid-state work). The right tool when an entire workflow — electrode handling, slitting, stacking or winding, electrolyte dosing, pre-formation sealing — has to come out of the glovebox and onto a pilot line.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe two are complementary, not interchangeable. A glovebox protects a workstation; a dryroom protects a process. Lithium-ion R\u0026amp;D and small-format prototyping usually start with a single-chamber glovebox. Pilot-scale pouch and cylindrical assembly moves into a dryroom, often with inert antechambers downstream for the moisture-sensitive final steps. Lithium-metal and sulfide solid-state programs typically need both: a deep-dew-point room around the line, and gloveboxes for cell closure.\u003c\/p\u003e\n\n\u003cp\u003eIf you are scoping a new battery lab, start with \u003ca href=\"\/collections\/gloveboxes\"\u003egloveboxes\u003c\/a\u003e; if you are scaling beyond coin-cell volumes, plan a \u003ca href=\"\/collections\/dryrooms\"\u003edryroom\u003c\/a\u003e. For upstream electrode fabrication and cell-build hardware, see \u003ca href=\"\/collections\/battery-equipment\"\u003ebattery equipment\u003c\/a\u003e.\u003c\/p\u003e\n","products":[{"product_id":"emscggps","title":"ECS-M Single-Chamber Glovebox with Gas Purification System (O2\/H2O \u003c1 ppm), EMSCGGPS","description":"\u003cp\u003eFor battery research and air-sensitive chemistry, a single-chamber glovebox is the standard workstation. It provides a controlled, inert atmosphere (typically Argon or Nitrogen) to keep moisture (H2O) and oxygen (O2) levels below 1 ppm. This ultra-dry, inert environment (typically Argon) is non-negotiable for handling lithium metal, specialized electrolytes (like LiPF6), and moisture-sensitive solid-state materials.\u003c\/p\u003e\n\u003cp\u003eWhen selecting a single-station glovebox for electrochemical research, the following configurations are standard: (1) \u003cstrong\u003eAtmosphere Control\u003c\/strong\u003e: Integrated purification column (Copper catalyst for O2 and Molecular Sieve for H2O) with a circulation blower. (2) \u003cstrong\u003eMaterial\u003c\/strong\u003e: 304 Stainless Steel chamber with a tempered glass or polycarbonate front window. Avoid acrylic if you are using solvents like NMP, as they can craze the plastic over time. (3) \u003cstrong\u003eAntechambers\u003c\/strong\u003e: A large cylindrical antechamber (e.g., Φ360 * 600 mm) for equipment like coaters or crimpers, and a mini-antechamber (Φ150 * 300 mm) for rapid sample and tool transfer. (4) \u003cstrong\u003eSolvent Trap\u003c\/strong\u003e: Essential if you are doing any electrolyte filling or coating. This prevents electrolyte vapors (DMC, DEC, EC) from poisoning the purification catalyst.\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003ePart Number\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMSCGGPS (EM-SCGGPS)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003ePower\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAC110-220V±10%, 50\/60Hz, 1500 W \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003eBox Features\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eInner Dimension: \u003cspan style=\"color: rgb(255, 42, 0);\"\u003eL1220 x D750 x H900 mm (For dual-side operation, the depth is 1000 mm)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eBox Frame: SS304, 3mm thickness \u003c\/li\u003e\n\u003cli\u003eFront Glass Door: 8mm\u003c\/li\u003e\n\u003cli\u003eButyl Gloves, thickness of 0.4 mm, D=7-8\"\u003c\/li\u003e\n\u003cli\u003eFilters: 0.3 um, one at gas inlet and one at the gas outlet\u003c\/li\u003e\n\u003cli\u003eTwo layers of shelves with adjustable height\u003c\/li\u003e\n\u003cli\u003eLED light inside and multiple DN40KF ports at backside. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e        \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/EMSCGGPS_02_100x100.png?v=1777371170\" alt=\"\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/EMSCGGPS_03_100x100.png?v=1777371170\" alt=\"\"\u003e   \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/EMDCGGPS_03_100x100.png?v=1777398069\" alt=\"\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003ePurification System\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePurification Materials: 5 kg Cu catalyst and 5 kg molecular sieve. \u003c\/li\u003e\n\u003cli\u003ePurification Capacity: 60 L O2 and 2 kg H2O\u003c\/li\u003e\n\u003cli\u003eO2 \u0026amp; H2O level: ＜1ppm (O2 measure level: 0-1000 cP, while H2O measure level: 500 cP)\u003c\/li\u003e\n\u003cli\u003eCirculation Capacity: integrated blower flow: 90m³\/h (even large one with 145 m³\/h and 180 m³\/h can be supplied upon request)\u003c\/li\u003e\n\u003cli\u003ePLC controlled regeneration with 5%H2\/Ar\u003c\/li\u003e\n\u003cli\u003eVacuum pump with a flow rate of 12 m3\/h (included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003eTransfer Chamber\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003cul\u003e\n\u003cli\u003eLarge antechamber size: \u003cspan style=\"color: rgb(255, 42, 0);\"\u003eD=360 mm, L=600 mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmall transfer chamber size: \u003cspan style=\"color: rgb(255, 42, 0);\"\u003eD=150 mm, L=300 mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSliding Tray is available on both transfer chamber\u003c\/li\u003e\n\u003cli\u003eA vacuum gauge is available for pressure display. \u003c\/li\u003e\n\u003cli\u003eThe rectangular transfer chamber is available upon request. The size for small and large transfer chambers are 120*150 mm and 250*300 mm, respectively. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e          \u003cimg style=\"float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/EMDCGGPS_04_100x100.png?v=1777398372\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHeating Function (\u003cspan\u003eOptional\u003c\/span\u003e): The heating unit with a maximum heating temperature of\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e 200°C\u003c\/span\u003e can be supplied upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003eControl System\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens PLC touch screen\u003c\/li\u003e\n\u003cli\u003eFoot pedal to adjust the box pressure\u003c\/li\u003e\n\u003cli\u003eData recording and can be log out for analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003eDimension\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eL1820 * W750 * H1810mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003eWeight\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e~700-800 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eReferences\u003c\/strong\u003e:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/onlinelibrary.wiley.com\/doi\/abs\/10.1002\/ente.202500591\"\u003eP. Ayyanusamy, et al., Real-Time Phase Monitoring of Solid-State Electrolytes: A Glovebox-Integrated In Situ Wide-Angle X-Ray Scattering, Energy Technology, 2025 ,13, 2500591\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/chemistry-europe.onlinelibrary.wiley.com\/doi\/full\/10.1002\/celc.202101161\"\u003eD. Martín-Yerga, et al., Scanning Electrochemical Cell Microscopy in a Glovebox: Structure-Activity Correlations in the Early Stages of Solid-Electrolyte Interphase Formation on Graphite, ChemElectroChem, 2021, 8, 4240-4251\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"MIKROUNA","offers":[{"title":"Singe-Side One Station","offer_id":47584595902694,"sku":"EMSCGGPSSS","price":8888888.0,"currency_code":"USD","in_stock":true},{"title":"Dual-Side Two Stations","offer_id":47584595935462,"sku":"EMSCGGPSDS","price":8888888.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/EMSCGGPS_main.png?v=1775203968"},{"product_id":"emdcggps","title":"ECS-M Dual-Chamber Glovebox with Gas Purification System (O2\/H2O \u003c1 ppm), EMDCGGPS","description":"\u003cp\u003eFor battery research and air-sensitive chemistry, a single-chamber glovebox is the standard workstation. It provides a controlled, inert atmosphere (typically Argon or Nitrogen) to keep moisture (H2O) and oxygen (O2) levels below 1 ppm. This ultra-dry, inert environment (typically Argon) is non-negotiable for handling lithium metal, specialized electrolytes (like LiPF6), and moisture-sensitive solid-state materials.\u003c\/p\u003e\n\u003cp\u003eWhen selecting a single-station glovebox for electrochemical research, the following configurations are standard: (1) \u003cstrong\u003eAtmosphere Control\u003c\/strong\u003e: Integrated purification column (Copper catalyst for O2 and Molecular Sieve for H2O) with a circulation blower. (2) \u003cstrong\u003eMaterial\u003c\/strong\u003e: 304 Stainless Steel chamber with a tempered glass or polycarbonate front window. Avoid acrylic if you are using solvents like NMP, as they can craze the plastic over time. (3) \u003cstrong\u003eAntechambers\u003c\/strong\u003e: A large cylindrical antechamber (e.g., Φ360 * 600 mm) for equipment like coaters or crimpers, and a mini-antechamber (Φ150 * 300 mm) for rapid sample and tool transfer. (4) \u003cstrong\u003eSolvent Trap\u003c\/strong\u003e: Essential if you are doing any electrolyte filling or coating. This prevents electrolyte vapors (DMC, DEC, EC) from poisoning the purification catalyst.\u003c\/p\u003e\n\u003ctable style=\"height: 1093.79px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 47.6px;\"\u003e\n\u003ctd style=\"width: 17.9856%; height: 47.6px;\"\u003e\u003cem\u003ePart Number\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%; height: 47.6px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eEMDCGGPS (EM-DCGGPS)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 47.6px;\"\u003e\n\u003ctd style=\"width: 17.9856%; height: 47.6px;\"\u003e\u003cem\u003ePower\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%; height: 47.6px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAC110-220V±10%, 50\/60Hz, 1800 W \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 295.987px;\"\u003e\n\u003ctd style=\"width: 17.9856%; height: 295.987px;\"\u003e\u003cem\u003eBox Features\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%; height: 295.987px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eInner Dimension: \u003cspan style=\"color: rgb(255, 42, 0);\"\u003eL2440 x D750 x H900 mm (For dual-side operation, the depth is 1000 mm)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eBox Frame: SS304, 3mm thickness \u003c\/li\u003e\n\u003cli\u003eFront Glass Door: 8mm\u003c\/li\u003e\n\u003cli\u003eButyl Gloves, thickness of 0.4 mm, D=7-8\"\u003c\/li\u003e\n\u003cli\u003eFilters: 0.3 um, one at gas inlet and one at the gas outlet\u003c\/li\u003e\n\u003cli\u003eTwo layers of shelves with adjustable height\u003c\/li\u003e\n\u003cli\u003eLED light inside and multiple DN40KF ports at backside. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e        \u003cimg style=\"float: none;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/EMDCGGPS_02_100x100.png?v=1777398002\"\u003e    \u003cimg height=\"87\" width=\"65\" style=\"float: none;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/EMSCGGPS_03_100x100.png?v=1777371170\"\u003e      \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/EMDCGGPS_03_100x100.png?v=1777398069\" alt=\"\" style=\"float: none;\" width=\"69\" height=\"91\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 184.8px;\"\u003e\n\u003ctd style=\"width: 17.9856%; height: 184.8px;\"\u003e\u003cem\u003ePurification System\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%; height: 184.8px;\"\u003e\n\u003cul\u003e\n\u003cli\u003ePurification Materials: 5 kg Cu catalyst and 5 kg molecular sieve. \u003c\/li\u003e\n\u003cli\u003ePurification Capacity: 60 L O2 and 2 kg H2O\u003c\/li\u003e\n\u003cli\u003eO2 \u0026amp; H2O level: ＜1ppm (O2 measure level: 0-1000 cP, while H2O measure level: 500 cP)\u003c\/li\u003e\n\u003cli\u003eCirculation Capacity: integrated blower flow: 90m³\/h (even large one with 145 m³\/h and 180 m³\/h can be supplied upon request)\u003c\/li\u003e\n\u003cli\u003ePLC controlled regeneration with 5%H2\/Ar\u003c\/li\u003e\n\u003cli\u003eVacuum pump with a flow rate of 12 m3\/h (included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 335.8px;\"\u003e\n\u003ctd style=\"width: 17.9856%; height: 335.8px;\"\u003e\u003cem\u003eTransfer Chamber\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%; height: 335.8px;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cul\u003e\n\u003cli\u003eLarge round antechamber size: \u003cspan style=\"color: rgb(255, 42, 0);\"\u003eD=360 mm, L=600 mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmall round transfer chamber size: \u003cspan style=\"color: rgb(255, 42, 0);\"\u003eD=150 mm, L=300 mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSliding Tray is available on both transfer chamber\u003c\/li\u003e\n\u003cli\u003eA vacuum gauge is available for pressure display. \u003c\/li\u003e\n\u003cli\u003eThe rectangular transfer chamber is available upon request. The size for small and large transfer chambers are 120*150 mm and 250*300 mm, respectively. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e           \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/EMDCGGPS_04_100x100.png?v=1777398372\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHeating Function (\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eOptional\u003c\/span\u003e): The heating unit with a maximum heating temperature of 200°C can be supplied upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 86.8px;\"\u003e\n\u003ctd style=\"width: 17.9856%; height: 86.8px;\"\u003e\u003ci\u003eControl System\u003c\/i\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%; height: 86.8px;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens PLC touch screen\u003c\/li\u003e\n\u003cli\u003eFoot pedal to adjust the box pressure\u003c\/li\u003e\n\u003cli\u003eData recording and can be log out for analysis   \u003cspan style=\"font-size: 0.875rem;\"\u003e         \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 47.6px;\"\u003e\n\u003ctd style=\"width: 17.9856%; height: 47.6px;\"\u003e\u003ci\u003eDimension\u003c\/i\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%; height: 47.6px;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cul\u003e\n\u003cli\u003eL2440 * W750 * H1810 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 47.6px;\"\u003e\n\u003ctd style=\"width: 17.9856%; height: 47.6px;\"\u003e\u003ci\u003eWeight\u003c\/i\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%; height: 47.6px;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cul\u003e\n\u003cli\u003e~700-800 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReferences\u003c\/strong\u003e:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/onlinelibrary.wiley.com\/doi\/abs\/10.1002\/ente.202500591\"\u003eP. Ayyanusamy, et al., Real-Time Phase Monitoring of Solid-State Electrolytes: A Glovebox-Integrated In Situ Wide-Angle X-Ray Scattering, Energy Technology, 2025 ,13, 2500591\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/chemistry-europe.onlinelibrary.wiley.com\/doi\/full\/10.1002\/celc.202101161\"\u003eD. Martín-Yerga, et al., Scanning Electrochemical Cell Microscopy in a Glovebox: Structure-Activity Correlations in the Early Stages of Solid-Electrolyte Interphase Formation on Graphite,  ChemElectroChem, 2021, 8, 4240-4251\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"MIKROUNA","offers":[{"title":"Single-Side Two Stations","offer_id":47585550467302,"sku":"EMDCGGPSSS","price":8888888.0,"currency_code":"USD","in_stock":true},{"title":"Dual-Side Four Stations","offer_id":47585550500070,"sku":"EMDCGGPSDS","price":8888888.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/EMDCGGPS_main.png?v=1777396522"},{"product_id":"etmigdr","title":"ECS-T Mini Industrial-Grade Dryroom (L8m*W3m*H2.2m, -40°C, Two Operator), ETMIGDR","description":"\u003cp\u003eFor high-precision research in Sodium-Ion (SIB) and Lithium-Sulfur (Li-S) batteries, a Mini Industrial-Grade Dryroom (also called a \"Mini-Environment\") is often a superior alternative to both a standard glovebox and a full-scale walk-in dryroom. It provides an encapsulated, ultra-dry workspace that can house multiple pieces of equipment\u003c\/p\u003e\n\u003cp\u003eAn industrial-grade mini-dryroom is defined by its ability to maintain \"Desert-Dry\" conditions under load. (1) \u003cstrong\u003eDew Point Control\u003c\/strong\u003e: Typically maintains -40°C to -60°C (less than 1% RH). For moisture-sensitive Sodium-Ion materials (like Prussian Blue), a stable -50°C dew point is the industry benchmark. (2) \u003cstrong\u003eCleanliness\u003c\/strong\u003e: Usually rated at ISO Class 6 or 7 (Class 1,000 to 10,000) to prevent metallic particle contamination during cell assembly. (3)\u003cstrong\u003e Temperature Stability\u003c\/strong\u003e: Precision control at 21°C ± 1°C. This is vital for maintaining the viscosity and dosing accuracy of electrolytes during vacuum filling.  (4) \u003cstrong\u003ePressure Management\u003c\/strong\u003e: Maintains a positive pressure (approx. 20–30 Pa) relative to the lab to prevent humid ambient air from leaking in through gaskets or door seals.\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"height: 1629.2px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 49.075px;\"\u003e\n\u003ctd style=\"height: 49.075px;\"\u003e\u003cem\u003ePart Number\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 49.075px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eETMIGDR (ET-MIGDR)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 149.913px;\"\u003e\n\u003ctd style=\"height: 149.913px;\"\u003e\u003cem\u003eCritical Targets\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 149.913px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eDryroom Space: L8m*W3m*H2.2m (larger or smaller can be customized according to equipment occupancy)\u003c\/li\u003e\n\u003cli\u003eDew point: \u003cspan style=\"color: rgb(255, 42, 0);\"\u003e-40°C \u003c\/span\u003e(other dew points can be achieved by choosing appropriate dehumidifier and water chiller). \u003c\/li\u003e\n\u003cli\u003eTwo Operators (more operators can be accommodated upon request for customization)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 345.2px;\"\u003e\n\u003ctd style=\"height: 345.2px;\"\u003e\u003cem\u003eDehumidifier Features\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 345.2px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAC380V±10%, three-phases, 50\/60Hz, 29.9 kW (total)\u003c\/li\u003e\n\u003cli\u003eDehumidifier: 20.4 kW (two heating regenerators, 11.5+8.9 kW)\u003c\/li\u003e\n\u003cli\u003eTemperature Control in Dryroom: 5 kW (Heating + Cooling)\u003c\/li\u003e\n\u003cli\u003eRegeneration \u0026amp; Processing Fan: 4.5 kW \u003c\/li\u003e\n\u003cli\u003eSupply Air Volume: 3000 m3\/h\u003c\/li\u003e\n\u003cli\u003eFresh Air Volume: 1000 m3\/h\u003c\/li\u003e\n\u003cli\u003eExhaust Air Volume: 300 m3\/h\u003c\/li\u003e\n\u003cli\u003eRegeneration Temperature: 130 °C (recommended). \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHMI touch screen to monitor and control all operation parameters.\u003c\/li\u003e\n\u003cli\u003eThe dehumidifier system is shown below for reference. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e         \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/ETMIGDR_03_160x160.png?v=1777569158\" alt=\"\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 333.263px;\"\u003e\n\u003ctd style=\"height: 333.263px;\"\u003e\u003cem\u003eWater Chiller Features\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 333.263px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAC380V±10%, three-phases, 50\/60Hz, 34.8 kW (total)\u003c\/li\u003e\n\u003cli\u003eAir cooled type, R134a refrigerating medium\u003c\/li\u003e\n\u003cli\u003eScroll Compressor: 11.05 kW and rated current 32 A.\u003c\/li\u003e\n\u003cli\u003eCondenser (surface area\/row): 1.92\/3 r\u003c\/li\u003e\n\u003cli\u003eWater Pump Power: 1.1 kW\u003c\/li\u003e\n\u003cli\u003eInlet and outlet water temperature: 12°C and 7°C, respectively.\u003c\/li\u003e\n\u003cli\u003eTank Volume: 130 L \u003c\/li\u003e\n\u003cli\u003eDimension: L1500mm * W780mm * H1600mm\u003c\/li\u003e\n\u003cli\u003eThe water chiller is shown below for reference. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e       \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/ETMIGDR_04_100x100.png?v=1777569157\" alt=\"\" style=\"float: none;\"\u003e     \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/ETMIGDR_05_100x100.png?v=1777569157\" alt=\"\" style=\"float: none;\" width=\"124\" height=\"93\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 751.75px;\"\u003e\n\u003ctd style=\"height: 751.75px;\"\u003e\u003cem\u003eDryroom Box Features\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 751.75px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eInner Dimension: L8m*W3m*H2.2m\u003c\/li\u003e\n\u003cli\u003eBox Frame: high-strength galvanized steel structure Q235 (anti-corrosion treatment)\u003c\/li\u003e\n\u003cli\u003eInside Wall Material: 50mm thick color steel plate (outer beige PVDF coated steel plate + rockwool\/paper honeycomb core material)\u003c\/li\u003e\n\u003cli\u003eAir Shower Room: inner stainless steel + outer spray\u003cbr\u003ecoating structure, equipped with HEPA efficient filtration system, which is in line with ISO 14644-1 Class 8 standard. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e          \u003cimg style=\"float: none;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/ETMIGDR_06_100x100.png?v=1777569157\"\u003e      \u003cimg height=\"98\" width=\"129\" style=\"float: none;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/ETMIGDR_09_100x100.png?v=1777571225\"\u003e    \u003cimg height=\"98\" width=\"128\" style=\"float: none;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/ETMIGDR_10_100x100.png?v=1777571225\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDouble-layer observation window: toughened glass and sealing tape\u003c\/li\u003e\n\u003cli\u003eSteel Safety Door: the door body is filled with fireproof rock wool, equipped with airtight strip and electronic interlock device to prevent external pollution intrusion and improve fire safety (fire\u003cbr\u003eresistance limit ≥1 hour). \u003c\/li\u003e\n\u003cli\u003eAir Distributor with Filtration Function: Built-in H13\/H14 HEPA filter, the filtration efficiency of ≥0.3μm particulate matter is ≥99.97%, to ensure that the air supply cleanliness meets the ISO 14644-1 Class 5-8 standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e          \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/ETMIGDR_07_100x100.png?v=1777569971\" alt=\"\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVentilation Duct: Galvanized air duct with high strength, corrosion resistance (surface galvanized layer ≥80g\/m²), good fire-resistance performance (class A non-combustible). \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e            \u003cimg style=\"float: none;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/ETMIGDR_08_100x100.png?v=1777570317\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReferences\u003c\/strong\u003e:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.sciencedirect.com\/science\/article\/abs\/pii\/S0378775316308199\"\u003eS. Ahmed, et al., Study of a dry room in a battery manufacturing plant using a process model, Journal of Power Sources, 2016 ,326, 490-497.\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.sciencedirect.com\/science\/article\/pii\/S2212827125006274\"\u003eE. Zeferino, et al., Assessing the impact of mini environments in lithium-ion battery production under uncertainties, Procedia CIRP, 2025, 134, 1053-1058.\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"TOB","offers":[{"title":"Default Title","offer_id":47592330854630,"sku":"ETMIGDR","price":8888888.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/ETMIGDR_main.png?v=1777569158"},{"product_id":"eselsd","title":"ECS-S Economic Lab-Scale Dryroom (L3-6m*W3m*H2.2m, -40°C, Two Operators), ESELSD","description":"\u003cp\u003eA lab-scale dryroom (or \"micro-dryroom\") is a modular, high-performance environment designed to bridge the gap between a glovebox and a full-scale industrial facility.\u003c\/p\u003e\n\u003cp\u003eA lab-scale dryroom must achieve \"Battery-Grade\" dry air while being compact enough to fit into an existing research facility. (1) \u003cstrong\u003eDew Point (Td)\u003c\/strong\u003e: The target is typically -40 to -55°C (\u0026lt;1% RH}). (2) \u003cstrong\u003eAir Changes per Hour (ACH)\u003c\/strong\u003e: Unlike a standard lab (6–10 ACH), a battery dryroom often requires 50+ ACH to maintain pressure and scrub moisture introduced by personnel or equipment.Filtration: Integrated HEPA filtration ensures ISO Class 6 or 7 cleanliness, preventing dust from causing micro-shorts in your pouch cells.\u003c\/p\u003e\n\u003ctable style=\"height: 1211.2px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 47.6px;\"\u003e\n\u003ctd style=\"height: 47.6px;\"\u003e\u003cem\u003ePart Number\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 47.6px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eESELSD (ES-ELSD)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 184.8px;\"\u003e\n\u003ctd style=\"height: 184.8px;\"\u003e\u003cem\u003eCritical Targets\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 184.8px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eDryroom Space: \u003cspan style=\"color: rgb(255, 42, 0);\"\u003eL3-6m*W3m*H2.2m\u003c\/span\u003e (larger or smaller space can be customized according to equipment occupancy)\u003c\/li\u003e\n\u003cli\u003eDew point: \u003cspan style=\"color: rgb(255, 42, 0);\"\u003e-40°C \u003c\/span\u003e(other dew points can be achieved by choosing appropriate dehumidifier and water chiller). \u003c\/li\u003e\n\u003cli\u003eTwo Operators (more operators can be accommodated upon request for customization)\u003c\/li\u003e\n\u003cli\u003eThe dryroom hosting space should have air condition system to maintain the environmental temperature (~22°C) and humidity. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 481.6px;\"\u003e\n\u003ctd style=\"height: 481.6px;\"\u003e\u003cem\u003eDehumidifier Features\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 481.6px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAC380V±10%, three-phases, 50\/60Hz, ~15 kW (for 3m*3m) or 28 kW for (3m*6m)\u003c\/li\u003e\n\u003cli\u003eA 25A or 50A air breaker should be installed\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupply Air Volume: 2000-4000 m3\/h (depends on the room size and operator numbers)\u003c\/li\u003e\n\u003cli\u003eFresh Air Volume: 500-1000 m3\/h\u003c\/li\u003e\n\u003cli\u003eExhaust Air Volume: 500-1000 m3\/h\u003c\/li\u003e\n\u003cli\u003eRegeneration Temperature: Max. 150 °C (normally 120-130 °C is recommended). \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eThree graded particle filtration system\u003cbr\u003e(1) Coarse filter: ≥ 5.0 um particles (eg: dust, hair);\u003cbr\u003e(2) Fine filter: 1-5 um particles;\u003cbr\u003e(3) Ultra-fine filter: ≥0.3 um particles. \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHMI touch screen to monitor and control all operation parameters. \u003c\/li\u003e\n\u003cli\u003eDimension: L2500mm * W1100mm * H2000mm (for 3m*6m, 4000 m3\/h)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e          \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/ESELSD_02_100x100.png?v=1777596443\" alt=\"\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 344.4px;\"\u003e\n\u003ctd style=\"height: 344.4px;\"\u003e\u003cem\u003eWater Chiller Features\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 344.4px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAC220V±10%, three-phases, 50\/60Hz, 8 kW (3m*3m), or 14 kW (3m*6m)\u003c\/li\u003e\n\u003cli\u003eAir cooled type, R32 refrigerating medium\u003c\/li\u003e\n\u003cli\u003eScroll Compressor: 2* 5.6 kW, cooling capacity: 45 kW. \u003c\/li\u003e\n\u003cli\u003eCondenser: High-efficiency fin type, \u003c\/li\u003e\n\u003cli\u003eWater Pump Power: 0.8 kW, 360 L\/min\u003c\/li\u003e\n\u003cli\u003eInlet and outlet water temperature: 12°C and 7°C, respectively.\u003c\/li\u003e\n\u003cli\u003eTank Volume: ~18 L \u003c\/li\u003e\n\u003cli\u003eDimension: L1590mm * W800mm * H1650mm\u003c\/li\u003e\n\u003cli\u003eThe water chiller is shown below for reference. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e           \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/ESELSD_03_100x100.png?v=1777605524\" alt=\"\" style=\"float: none;\"\u003e   \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 152.8px;\"\u003e\n\u003ctd style=\"height: 152.8px;\"\u003e\u003cem\u003eDryroom Box Features\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 152.8px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eInner Dimension: L3-6m*W3m*H2.2m\u003c\/li\u003e\n\u003cli\u003eBox Frame: Aluminum alloy frame with acrylic plates\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuffer Room: it is designed for \"buffering\" the humidity from operator and outside when opening the door. \u003c\/li\u003e\n\u003cli\u003eTwo LED light panels are included.\u003c\/li\u003e\n\u003cli\u003eThe dry air distribution plates are presented.\u003c\/li\u003e\n\u003cli\u003eThe electrical box with AC110V\/AC220V input, as well as tubing ports (for gas\/cable\/eye wash water) are available. \u003c\/li\u003e\n\u003cli\u003eA dew point display is installed inside dryroom.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e          \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/ESELSD_04_100x100.png?v=1777607775\" alt=\"\" style=\"float: none;\"\u003e      \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/ESELSD_05_100x100.png?v=1777607918\" alt=\"\" style=\"float: none;\" width=\"110\" height=\"96\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReferences\u003c\/strong\u003e:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.sciencedirect.com\/science\/article\/abs\/pii\/S0378775316308199\"\u003eS. Ahmed, et al., Study of a dry room in a battery manufacturing plant using a process model, Journal of Power Sources, 2016 ,326, 490-497.\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.sciencedirect.com\/science\/article\/pii\/S2212827125006274\"\u003eE. Zeferino, et al., Assessing the impact of mini environments in lithium-ion battery production under uncertainties, Procedia CIRP, 2025, 134, 1053-1058.\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"SZKJ","offers":[{"title":"3m*3m (-40°C\/Two Operators)","offer_id":47597265813734,"sku":"ESELSD33","price":8888888.0,"currency_code":"USD","in_stock":true},{"title":"3m*6m (-40°C\/Two Operators)","offer_id":47597265846502,"sku":"ESELSD36","price":8888888.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/ESELSD_02.png?v=1777596443"}],"url":"https:\/\/echemsupplies.com\/collections\/controlled-atmosphere-systems.oembed","provider":"EChem Supplies","version":"1.0","type":"link"}