{"product_id":"cmbblsedts","title":"ECS-MB Benchtop Lab-Scale Electrodialysis (ED) Testing System, CMBBLSEDTS","description":"\u003cp\u003eA Benchtop Lab-Scale Electrodialysis (ED) Testing System is a compact, highly versatile electrochemical separation unit designed for academic research, feasibility studies, membrane screening, and small-volume wastewater treatment, desalination, or mineral extraction process development.\u003c\/p\u003e\n\u003cp\u003eThe key components of the ED testing system are: (1) \u003cstrong\u003eMembrane Stack (\"The Heart\")\u003c\/strong\u003e: Configured with alternating Anion-Exchange Membranes (AEMs) and Cation-Exchange Membranes (CEMs)—such as low-resistance hydrocarbon or perfluorinated sheets—separated by specialized flow-distributing gaskets\/spacers to create repeating cell pairs (Diluate and Concentrate chambers). The end plates constructed of rugged transparent materials (like acrylic or PTFE) coupled with titanium or DSA (Dimensionally Stable Anode) current-collector electrodes. (2) \u003cstrong\u003eFluid Handling \u0026amp; Hydraulic Loops\u003c\/strong\u003e: (i) \u003cem\u003eMulti-Channel Peristaltic or Magnetic Drive Pumps\u003c\/em\u003e: Independent closed-loop or open-loop circulation circuits for the diluate stream, concentrate (brine) stream, and electrode rinse solution (typically maintained separately to prevent chlorine gas evolution or pH polarization at the electrodes). (ii) \u003cem\u003eFeed Reservoirs\u003c\/em\u003e: Pyrex glass or polypropylene tanks (typically 0.5 L to 2.0 L capacity for lab-scale systems) equipped with sampling ports and temperature probes. (3) \u003cstrong\u003eInstrumentation \u0026amp; Control Package\u003c\/strong\u003e: (i) \u003cem\u003eDC Power Supply\u003c\/em\u003e: High-stability, low-ripple DC source operating under constant current or constant voltage modes. (2) \u003cem\u003eInline Sensors\u003c\/em\u003e: Real-time digital monitoring for conductivity (to track ion depletion\/desalination kinetics), pH (to monitor water splitting or acid\/base generation), and temperature. (iii) P\u003cem\u003eressure Gauges \u0026amp; Flow Meters\u003c\/em\u003e: Rotameters or digital mass\/volume flow sensors paired with needle valves to balance hydraulic pressures across the delicate membrane stack and prevent internal cross-leaks.\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 1382.4px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 47.6px;\"\u003e\n\u003ctd style=\"width: 33.0409%; height: 47.6px;\"\u003e\u003cem\u003ePart Number\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6667%; height: 47.6px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCMBBLSEDTS (CMB-BLSEDTS)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 67.2px;\"\u003e\n\u003ctd style=\"width: 33.0409%; height: 67.2px;\"\u003e\u003cem\u003eInput Power\/Voltage\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6667%; height: 67.2px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAC220V±10%, single-phase, 50\/60 Hz, 800 W\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOutput DC voltage: 16 V; output DC current: 10 A\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 979.2px;\"\u003e\n\u003ctd style=\"width: 33.0409%; height: 979.2px;\"\u003e\u003cem\u003eTesting Cells\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6667%; height: 979.2px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e(1) Testing cell with two chamber design (20cm*10cm) that can be used for the following conditions:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e              (i) CEM + AEM mode\u003c\/p\u003e\n\u003cp\u003e            \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/CMBBLSEDTS_sketch_01_240x240.png?v=1792961661\" alt=\"\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cp\u003e              (ii) BPM + CEM mode\u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e              \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/CWTMEBMEDC_04_240x240.jpg?v=1792800132\" alt=\"\" style=\"float: none;\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e               (ii) BPM + AEM mode\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e                    \u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003cp\u003e            \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/CWTMEBMEDC_03_240x240.jpg?v=1792800340\" style=\"float: none;\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e(2) The testing cell with three chambers that is composed of bipolar membrane, AEM, CEM, polar membrane, and polar plate.\n\u003cp\u003e    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/CWTMEBMEDC_02_240x240.jpg?v=1792798761\" alt=\"\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eChamber Material: Graphite manifold\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSealing Gasket: PTFE\u003c\/li\u003e\n\u003cli\u003eActive Area: 20cm*10cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 86.8px;\"\u003e\n\u003ctd style=\"width: 33.0409%; height: 86.8px;\"\u003e\u003cem\u003eFlow Pump\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6667%; height: 86.8px;\"\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003cul\u003e\n\u003cli\u003eFlow pump speed: 1-30 mL\/min\u003c\/li\u003e\n\u003cli\u003eFour separated flow channes\u003c\/li\u003e\n\u003cli\u003eReservoirs and tubing are included for systematic testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 67.2px;\"\u003e\n\u003ctd style=\"width: 33.0409%; height: 67.2px;\"\u003e\u003cem\u003eControl Unit \u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6667%; height: 67.2px;\"\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003cul\u003e\n\u003cli\u003ePLC control system is used for integrating of operation functions\u003c\/li\u003e\n\u003cli\u003eHMI touch screen for convenient operation \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 67.2px;\"\u003e\n\u003ctd style=\"width: 33.0409%; height: 67.2px;\"\u003e\u003cem\u003eMembranes for ED (\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eOptional\u003c\/span\u003e)\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6667%; height: 67.2px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eCEM: such as \u003ca href=\"https:\/\/echemsupplies.com\/products\/ceeanaem?variant=47480853627110\u0026amp;amp;_pos=1\u0026amp;amp;_sid=d6e637183\u0026amp;amp;_ss=r\"\u003eCEEHBPM\u003c\/a\u003e, \u003ca href=\"https:\/\/echemsupplies.com\/products\/ceeanaem?variant=47480853627110\u0026amp;_pos=1\u0026amp;_sid=d6e637183\u0026amp;_ss=r\"\u003eCEEANCEM\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eAEM: such as \u003ca href=\"https:\/\/echemsupplies.com\/products\/ceeanaem?variant=47480853627110\u0026amp;_pos=1\u0026amp;_sid=d6e637183\u0026amp;_ss=r\"\u003eCEEANAEM\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 67.2px;\"\u003e\n\u003ctd style=\"width: 33.0409%; height: 67.2px;\"\u003e\u003cem\u003eNote\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6667%; height: 67.2px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe cell components should be thoroughly cleaned and dried after use. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReferences\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003e1. \u003ca href=\"https:\/\/www.sciencedirect.com\/science\/article\/abs\/pii\/S0011916419302061\"\u003eS. Abu Khalla, et al., Desalination via chemical energy: An electrodialysis cell driven by spontaneous electrode reactions, Desalination, 2019, 467, 418-427.\u003c\/a\u003e \u003c\/p\u003e\n\u003cp\u003e2.\u003ca href=\"https:\/\/pubs.acs.org\/doi\/abs\/10.1021\/acsaem.4c02926\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/advanced.onlinelibrary.wiley.com\/doi\/full\/10.1002\/adsu.202400402\"\u003eM. Amores, et al. Electrodialysis as a Method for LiOH Production: Cell Configurations and Ion-Exchange Membranes, Adv. Sustain. Mater.\u003cspan class=\"cit-title\"\u003e\u003ci\u003e,\u003c\/i\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"cit-year-info\"\u003e\u003cspan\u003e2025\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"cit-volume\"\u003e, 9\u003c\/span\u003e\u003cspan class=\"cit-pageRange\"\u003e, 2400402\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"MBPD","offers":[{"title":"Default Title","offer_id":67850315825382,"sku":"CMBBLSEDTS","price":6999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/CMBBLSEDTS_main_01.jpg?v=1792963072","url":"https:\/\/echemsupplies.com\/products\/cmbblsedts","provider":"EChem Supplies","version":"1.0","type":"link"}