{"product_id":"cmbmedts","title":"ECS-MB Medium Electrodialysis (ED) Testing System, CMBMEDTS","description":"\u003cp\u003eA medium-scale (bench-to-pilot transition) Electrodialysis (ED) or Bipolar Membrane Electrodialysis (BMED) testing system sits squarely between a micro-volume desktop unit and a large industrial skid. It is engineered for advanced R\u0026amp;D, process optimization, and small-batch production validation—providing realistic hydrodynamic and mass-transfer data without requiring large fluid volumes.\u003c\/p\u003e\n\u003cp\u003eThe typical structural features of the medium electrodialysis testing system are: (1) \u003cstrong\u003eMembrane Stack Capacity\u003c\/strong\u003e: Typically houses 10 to 30 cell pairs (compared to 5–10 in micro-bench units and 50–200+ in industrial stacks). Effective membrane active area per sheet ranges from 100 cm2 to 200 cm2 (e.g., standard 10 cm* 10 cm or 15 cm * 20 cm frames). (2) \u003cstrong\u003eProcessing Volume \u0026amp; Flow Rate\u003c\/strong\u003e: Designed for batch volumes of 10 L to 50 L per run, operating with recirculation flow rates between 1 L\/min and 10 L\/min to simulate real-world linear velocities and turbulence promoter efficiency. (3) \u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e: Typically paired with a DC power supply ranging from 0-30 V to 0-50 V at currents up to 10 A to 20 A, accommodating higher ionic loading than basic desktop cells.\u003c\/p\u003e\n\u003cp\u003eThe main application fields are: (1) \u003cstrong\u003eProcess Scale-Up \u0026amp; Kinetic Modeling\u003c\/strong\u003e: Generating reliable limiting current density curves, electrical resistance profiles, and specific energy consumption data (kWh\/m3) needed to design full-scale industrial ED plants. (2) \u003cstrong\u003eOrganic Acid \u0026amp; Fine Chemical Deacidification\u003c\/strong\u003e: Purifying high-value fermentation broths, pharmaceutical intermediates, or food process streams by selectively removing inorganic salts without altering neutral organic components. (3) \u003cstrong\u003eTargeted Ion Recovery \u0026amp; Wastewater Polishing\u003c\/strong\u003e: Concentrating specific heavy metals, mining leachates, or valuable alkali salts from industrial effluent streams down to strict discharge or recovery limits.\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 1382.4px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 47.6px;\"\u003e\n\u003ctd style=\"width: 33.0409%; height: 47.6px;\"\u003e\u003cem\u003ePart Number\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6667%; height: 47.6px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCMBMEDTS (CMB-MEDTS)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 67.2px;\"\u003e\n\u003ctd style=\"width: 33.0409%; height: 67.2px;\"\u003e\u003cem\u003eInput Power\/Voltage\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6667%; height: 67.2px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAC220V±10%, single-phase, 50\/60 Hz, 2000 W\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOutput DC voltage: 50 V; output DC current: 30 A\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 979.2px;\"\u003e\n\u003ctd style=\"width: 33.0409%; height: 979.2px;\"\u003e\n\u003cp\u003e\u003cem\u003eTesting Cells (\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eOptional and Customizable, purchase separately\u003c\/span\u003e)\u003c\/em\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/echemsupplies.com\/products\/cwtmebmedc?variant=67839604359398\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/CWTMEBMEDC_main_160x160.jpg?v=1792800933\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 66.6667%; height: 979.2px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e(1) Testing cell with two chamber design (20cm*10cm) that can be used for the following conditions:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e              (i) CEM + AEM mode\u003c\/p\u003e\n\u003cp\u003e            \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/CMBBLSEDTS_sketch_01_240x240.png?v=1792961661\" alt=\"\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cp\u003e              (ii) BPM + CEM mode\u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e              \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/CWTMEBMEDC_04_240x240.jpg?v=1792800132\" alt=\"\" style=\"float: none;\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e               (ii) BPM + AEM mode\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e                    \u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003cp\u003e            \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/CWTMEBMEDC_03_240x240.jpg?v=1792800340\" style=\"float: none;\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e(2) The testing cell with three chambers that is composed of bipolar membrane, AEM, CEM, polar membrane, and polar plate.\n\u003cp\u003e    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/CWTMEBMEDC_02_240x240.jpg?v=1792798761\" alt=\"\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eChamber Material: Graphite manifold\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSealing Gasket: PTFE\u003c\/li\u003e\n\u003cli\u003eMembrane Size: \u003cspan\u003e(1) 20cm*10cm (active area is 10cm*7.5 cm); (2) 30cm*14cm (active area is 15cm*10cm); (3) 40cm*20cm (active area is 20cm*15cm)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarger sizes can be customized upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.0409%;\"\u003e\u003cem\u003eWater Tank Volume\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6667%;\"\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003cul\u003e\n\u003cli\u003e4 L\u003c\/li\u003e\n\u003cli\u003eMinimal circulation volume is 1 L\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 86.8px;\"\u003e\n\u003ctd style=\"width: 33.0409%; height: 86.8px;\"\u003e\u003cem\u003eFlow Pump\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6667%; height: 86.8px;\"\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003cul\u003e\n\u003cli\u003eFlow pump speed: 1-50 mL\/min\u003c\/li\u003e\n\u003cli\u003eFour separated flow channes\u003c\/li\u003e\n\u003cli\u003eReservoirs and tubing are included for systematic testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 67.2px;\"\u003e\n\u003ctd style=\"width: 33.0409%; height: 67.2px;\"\u003e\u003cem\u003eControl Unit \u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6667%; height: 67.2px;\"\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003cul\u003e\n\u003cli\u003ePLC control system is used for integrating of operation functions\u003c\/li\u003e\n\u003cli\u003eHMI touch screen for convenient operation \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 67.2px;\"\u003e\n\u003ctd style=\"width: 33.0409%; height: 67.2px;\"\u003e\u003cem\u003eMembranes for ED (\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eOptional\u003c\/span\u003e)\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6667%; height: 67.2px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eCEM: such as \u003ca href=\"https:\/\/echemsupplies.com\/products\/ceeancem?variant=47480652300518\"\u003eCEEANCEM\u003c\/a\u003e, \u003ca href=\"https:\/\/echemsupplies.com\/products\/cedhcemcmhe?variant=48379197751526\"\u003eCEDHCEMCMHE\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eAEM: such as \u003ca href=\"https:\/\/echemsupplies.com\/products\/ceeanaem?variant=47480853627110\"\u003eCEEANAEM\u003c\/a\u003e, \u003ca href=\"https:\/\/echemsupplies.com\/products\/cedhaemamhn?variant=48375670538470\"\u003eCEDHAEMAMHN\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eBPM: such as \u003ca href=\"https:\/\/echemsupplies.com\/products\/ceeanbmbpu?variant=48375550378214\"\u003eCEEANBMBPU\u003c\/a\u003e, \u003ca href=\"https:\/\/echemsupplies.com\/products\/ceehbpm?variant=48207491006694\"\u003eCEEHBPM\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 67.2px;\"\u003e\n\u003ctd style=\"width: 33.0409%; height: 67.2px;\"\u003e\u003cem\u003eDimension\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6667%; height: 67.2px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eL700mm * W600mm * H900mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.0409%;\"\u003e\u003cem\u003eWeight\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.6667%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e~80 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReferences\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003e1. \u003ca href=\"https:\/\/www.sciencedirect.com\/science\/article\/abs\/pii\/S0011916419302061\"\u003eS. Abu Khalla, et al., Desalination via chemical energy: An electrodialysis cell driven by spontaneous electrode reactions, Desalination, 2019, 467, 418-427.\u003c\/a\u003e \u003c\/p\u003e\n\u003cp\u003e2.\u003ca href=\"https:\/\/pubs.acs.org\/doi\/abs\/10.1021\/acsaem.4c02926\"\u003e \u003c\/a\u003e\u003ca href=\"https:\/\/advanced.onlinelibrary.wiley.com\/doi\/full\/10.1002\/adsu.202400402\"\u003eM. Amores, et al. Electrodialysis as a Method for LiOH Production: Cell Configurations and Ion-Exchange Membranes, Adv. Sustain. Mater.\u003cspan class=\"cit-title\"\u003e\u003ci\u003e,\u003c\/i\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"cit-year-info\"\u003e\u003cspan\u003e2025\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"cit-volume\"\u003e, 9\u003c\/span\u003e\u003cspan class=\"cit-pageRange\"\u003e, 2400402\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"MBPD","offers":[{"title":"Default Title","offer_id":67953097572582,"sku":"CMBMEDTS","price":8999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/CMBMEDTS_main.jpg?v=1793731147","url":"https:\/\/echemsupplies.com\/products\/cmbmedts","provider":"EChem Supplies","version":"1.0","type":"link"}