{"product_id":"enbscmfctc","title":"ECS-N Benchtop Single-Channel Mass Flow Controller (MFC, 200 SCCM) with Touch Screen, ENBSCMFCTC","description":"\u003cp\u003eA Benchtop Single-Channel Mass Flow Controller with Touch Screen is a standalone, plug-and-play gas delivery instrument designed for laboratory and pilot-scale environments. Unlike standard bare OEM mass flow controllers (MFCs) that require external DC power supplies, separate breakout boxes, or PC software control, these integrated units combine the gas flow measurement sensor, PID proportional valve, internal power supply, and a color touchscreen HMI (Human-Machine Interface) into a compact desktop enclosure.\u003c\/p\u003e\n\u003cp\u003eThe key Advantages of Touch Screen Benchtop Units are: (1) \u003cstrong\u003eStand-Alone Operation\u003c\/strong\u003e: Set flow rates directly on the display without needing an external computer, PLC, or analog signal generator. (2) \u003cstrong\u003eReal-Time Visualization \u0026amp; Totalization\u003c\/strong\u003e: The graphical display monitors instantaneous mass flow, total accumulated gas volume (totalizer), system pressure, and alarms in real time. (3) \u003cstrong\u003eMulti-Gas Selection\u003c\/strong\u003e: Units often feature built-in conversion factors or multi-gas libraries (e.g., N2, Ar, He, H2, CO2, O2), allowing users to switch gas types directly via touch menus. (4) \u003cstrong\u003eProgrammable Flow Profiles\u003c\/strong\u003e: Many models support multi-step gas dosing recipes, ramping rates, and timed purge cycles directly from the on-screen menu.  \u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"height: 593.2px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 47.6px;\"\u003e\n\u003ctd style=\"height: 47.6px;\"\u003e\u003cem\u003ePart Number\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 47.6px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eENBSCMFCTC (EN-BSCMFCTC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 47.6px;\"\u003e\n\u003ctd style=\"height: 47.6px;\"\u003e\u003cem\u003ePower\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 47.6px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAC220V±10%, single phase, 50\/60 Hz, 50 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 162px;\"\u003e\n\u003ctd style=\"height: 162px;\"\u003e\u003cem\u003eWorkflow\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 162px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eBefore connecting the gas cylinder, close all valve and plug the power and turn it on\u003c\/li\u003e\n\u003cli\u003eConnect the MFC with gas cylinder and open the valve of gas pressure regulator. Check if any leaking happens.\u003c\/li\u003e\n\u003cli\u003eOpen the gas inlet valve and slowly rotate it until target pressure value reached (Pmax \u0026lt;0.05 MPa). \u003c\/li\u003e\n\u003cli\u003eAdjust the output gas flow to target value\u003c\/li\u003e\n\u003cli\u003eWhen the experiment finished, release the pressure in cabinet and close all valves.\u003c\/li\u003e\n\u003cli\u003eTurn off and shut down the power. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 126px;\"\u003e\n\u003ctd style=\"height: 126px;\"\u003e\u003cem\u003eMFC Features\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 126px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eFlow Meter Type: Mass Flow Controller\u003c\/li\u003e\n\u003cli\u003eGas Inlet Number: 1 channel\u003c\/li\u003e\n\u003cli\u003eConnection Port Size: 1\/4\" Bi-Lok\u003c\/li\u003e\n\u003cli\u003eMeasurement Resolution: ±1.0%F.S\u003c\/li\u003e\n\u003cli\u003eMeasurement Range: 0-200 SCCM\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 67.2px;\"\u003e\n\u003ctd style=\"height: 67.2px;\"\u003e\u003cem\u003eNotes\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 67.2px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eMake sure the tubing pressure\u0026lt;0.15 MPa\u003c\/li\u003e\n\u003cli\u003eAfter connection, soap water can be used for gas leaking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 47.6px;\"\u003e\n\u003ctd style=\"height: 47.6px;\"\u003e\u003cem\u003eWarranty\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 47.6px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eOne-year warranty and lift-time technical support\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 47.6px;\"\u003e\n\u003ctd style=\"height: 47.6px;\"\u003e\u003cem\u003eDimension\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 47.6px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eL530 * D520 * H245 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 47.6px;\"\u003e\n\u003ctd style=\"height: 47.6px;\"\u003e\u003cem\u003eWeight\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 47.6px;\"\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e~11 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"NBD","offers":[{"title":"Default Title","offer_id":48200090583270,"sku":"ENBSCMFCTC","price":4499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/ENBSCMFCTC_main.jpg?v=1786763873","url":"https:\/\/echemsupplies.com\/products\/enbscmfctc","provider":"EChem Supplies","version":"1.0","type":"link"}