{"product_id":"erpcfsas","title":"ECS-R Floor-Stand Automatic Stacker (L150mm x W150mm) for Pouch Cells, ERPCFSAS","description":"\u003cp\u003eFor pouch cell research, an automatic stacking machine is the most critical tool for transitioning from single-layer prototypes to multi-layer high-energy cells. These machines automate the precise \"Z-fold\" layering of cathodes, anodes, and separators, ensuring the alignment and tension required for high-performance electrochemical testing. The separator is supplied as a continuous web from a tension-controlled roll, while pre-cut anode and cathode sheets are inserted into the folds from opposite sides. This creates a compact, interconnected stack that is superior to simple manual layering.\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"height: 1256.2px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 47.6px;\"\u003e\n\u003ctd style=\"width: 17.9856%; height: 47.6px;\"\u003e\u003cem\u003ePart Number\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%; height: 47.6px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eERPCFSAS (ER-PC-FSAS)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 47.6px;\"\u003e\n\u003ctd style=\"width: 17.9856%; height: 47.6px;\"\u003e\u003cem\u003ePower\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%; height: 47.6px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAC110 or 220V±10%, single phase, 50\/60Hz, 3000 W \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 17.9856%;\"\u003e\u003cem\u003eMain Features\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eMechanical arm for automatic electrode pick-up\u003c\/li\u003e\n\u003cli\u003eAutomatic separator release with alignment and constant tension control \u003c\/li\u003e\n\u003cli\u003eAutomatic stacking \u003c\/li\u003e\n\u003cli\u003eAutomatic separator cutting after stacking\u003c\/li\u003e\n\u003cli\u003eMechanical arm to take the stacked cell out\u003c\/li\u003e\n\u003cli\u003eManual taping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 226.8px;\"\u003e\n\u003ctd style=\"width: 17.9856%; height: 226.8px;\"\u003e\u003cem\u003eAcceptable Electrode Sizes\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%; height: 226.8px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eL: 40-190 mm, W 40-150 mm (tab is not countered). Normally a max tab length is 15 mm\u003c\/li\u003e\n\u003cli\u003eAny customized electrodes are supposed to disclose the electrode\/tab size and layout.\u003c\/li\u003e\n\u003cli\u003eFor customized electrode sizes, a corresponding stacking die set is required. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e           \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/ESSPCPESC_03_100x100.png?v=1774910247\" alt=\"\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 282.6px;\"\u003e\n\u003ctd style=\"width: 17.9856%; height: 282.6px;\"\u003e\u003cem\u003eStacking Features\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%; height: 282.6px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eStacking Mode: Regular \u003cstrong\u003eZ-fold\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e           \u003c\/strong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/ESSPCBAS_02_100x100.png?v=1775241692\" alt=\"\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax. stacking layers: 500 (adjustable)\u003c\/li\u003e\n\u003cli\u003eMax. stacking cell thickness: 30 mm\u003c\/li\u003e\n\u003cli\u003eSeparator Alignment Accuracy: ±0.3 mm\u003c\/li\u003e\n\u003cli\u003eStacking cell alignment accuracy: ±0.5 mm\u003c\/li\u003e\n\u003cli\u003eStacking Speed: 4-6 s\/layer for regular electrode (6-8s\/layer for lithium metal)\u003c\/li\u003e\n\u003cli\u003eA vacuum pump is built-in for sucking electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 67.2px;\"\u003e\n\u003ctd style=\"width: 17.9856%; height: 67.2px;\"\u003e\u003cem\u003eLoading Separator Roll\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%; height: 67.2px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eCardboard core size: 3\"\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMax. Roll diameter: 250 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 67.2px;\"\u003e\n\u003ctd style=\"width: 17.9856%; height: 67.2px;\"\u003e\u003cem\u003eSafety Feature\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%; height: 67.2px;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAn acrylic frame cover \u0026amp; door can be customized to improve operation safety.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 335.2px;\"\u003e\n\u003ctd style=\"width: 17.9856%; height: 335.2px;\"\u003e\u003cem\u003eGas Pressure Source (\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eOptional\u003c\/span\u003e)\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%; height: 335.2px;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cul\u003e\n\u003cli\u003eWhen the stacker is placed inside a dryroom or regular room, a gas compressor (\u003ca href=\"https:\/\/echemsupplies.com\/products\/euqofgc?variant=47513044156646\"\u003eEUQOFGC\u003c\/a\u003e) is required to supply a 60-80 psi for pneumatic operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e           \u003ca href=\"https:\/\/echemsupplies.com\/products\/euqofgc?variant=47513044156646\"\u003e\u003cimg style=\"float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/EUQOFGC_main_100x100.png?v=1775414665\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe KF40 feedthrough was included for glovebox operation (sensitive electrodes or solid-state electrolyte). In this case, an Ar gas tank with second-stage regulator is supposed to be placed outside through the feedthrough for provide pneumatic gas pressure.   \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 86.8px;\"\u003e\n\u003ctd style=\"width: 17.9856%; height: 86.8px;\"\u003e\u003cem\u003eCertificate\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%; height: 86.8px;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cul\u003e\n\u003cli\u003eCE certificate\u003c\/li\u003e\n\u003cli\u003eUL and CSA certificate are available upon request with additional charge\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 47.6px;\"\u003e\n\u003ctd style=\"width: 17.9856%; height: 47.6px;\"\u003e\u003ci\u003eDimension\u003c\/i\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%; height: 47.6px;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cul\u003e\n\u003cli\u003eL1650 * W1050 * H1800 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 47.6px;\"\u003e\n\u003ctd style=\"width: 17.9856%; height: 47.6px;\"\u003e\u003ci\u003eWeight\u003c\/i\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 81.6547%; height: 47.6px;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cul\u003e\n\u003cli\u003e~616 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReferences\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.sciencedirect.com\/science\/article\/abs\/pii\/S0007850612001035\"\u003eJ. Kurfer, et al., Production of large-area lithium-ion cells – Preconditioning, cell stacking and quality assurance, CIRP Annals, 2012, 61, 1-4\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/pubs.rsc.org\/en\/content\/articlelanding\/2017\/sc\/c8ee00546j\/unauth\"\u003eB. Evanko, et al., Stackable bipolar pouch cells with corrosion-resistant current collectors enable high-power aqueous electrochemical energy storage, Energy Environ. Sci., 2018,11, 2865-2875\u003c\/a\u003e.\u003c\/p\u003e","brand":"RSC","offers":[{"title":"Default Title","offer_id":47934542381286,"sku":"ERPCFSAS","price":34999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0774\/6591\/1526\/files\/ERPCFSAS_main.jpg?v=1782756716","url":"https:\/\/echemsupplies.com\/products\/erpcfsas","provider":"EChem Supplies","version":"1.0","type":"link"}